Hayward GL-235 Solar Pool Controller
The Hayward GL-235 Aqua Solar is a solar pool controller that uses the temperature difference between pool water and solar collectors to manage solar heating for pools, spas and hot tubs. Its microprocessor-based design provides automatic temperature control with a single desired-temperature dial. This is a control device for a solar heating system, not a standalone heater.
Automatic heating and cooling
Solar heating starts when the collector sensor is at least 4°F warmer than the pool water and the water is below the selected temperature. Heating stops when the temperatures are within 1.5°F or the water exceeds the desired setting. The calibrated desired-temperature scale is 70°F to 104°F.
Optional nocturnal cooling uses the solar collectors to dissipate excess pool heat. This feature is field-selectable and is disabled at the factory. Follow the manufacturer's instructions for configuration and operation.
Control features and connections
- The adjustable water-temperature high limit helps control solar heat collection.
- The fuse-protected valve output is factory-set to 24 VAC and can be changed by an internal jumper to 12 VAC for compatible older actuators.
- Industry-standard 3-pin actuator connectors support either direction of valve operation; screw terminals accommodate actuators without plug connectors.
- A high-voltage output supports optional booster-pump control or filter-pump timer override.
- Terminal-strip connections are provided for input power and temperature sensors.
- Four LED indicators show power, heating, cooling and sensor-fault status.
- A manual test switch allows operation to be checked independently of automatic temperature control.
Sensor requirements and specifications
- Two thermistor sensors rated at 10K ohms at 77°F (25°C) are required: one for pool water and one for the solar collectors.
- The control accepts nominal 115 VAC or 240 VAC input power when wired as specified in the installation manual.
- Controller dimensions are 8 inches high × 6 inches wide × 4 inches deep.
Recirculation freeze-protection limitations
Optional recirculation freeze protection is field-selectable and disabled at the factory. When enabled, it permits warmer pool water to circulate through the collectors below 40°F and stops recirculation above 42°F. Hayward strongly recommends GC-3 freeze snap switches when this feature is used.
This feature is intended for relatively mild climates and is not recommended where freezing temperatures are common or prolonged. It does not protect the system during a power failure. Recirculation freeze protection and nocturnal cooling require continuous filter-pump operation or the specified timer-override wiring. Follow Hayward's installation manual before enabling either feature.
Est. 4-6 business days for delivery.
-
Free Shipping On orders over $100
-
30-Day Returns Easy return policy
-
Warranty Manufacturer warranty included



Key Features
- Automatically maximizes solar heat collection by actuating a 24V valve when there is solar heat available LED indicators show status of system operations Automatic switching (selectable) from solar pool heating to nocturnal pool cooling Single-setting adjustment for desired pool/spa temperature Recirculation freeze protection Installer-programmable features for any-system adaptability Quick, accurate, easy-to-set desired temperature controls Easy to read, understand and operate Two sensors required (thermistor, 10Kohm at 25C/77 Deg F) sold separately